Main Standard: ETSI
Low Power Consumption
High Security
Easy Installation
4.4GHZ_16E1_11
15GHZ_16E1_11
18GHZ_16E1_11
23GHZ_16E1_10
ODU (Outdoor Unit):
Dimensions: (H×W×D:148*242*274.5
Weight :17kg
Temperature range: -33 ~ + 55 C
Power consumption: < 75 Watt
Box Test point: AGC
Configuration 1+1
System Parameters:
Frequency range: 4.4 to 5GHz (ITU-R F.636-3)
Frequency step : 1 MHz
Modulation type : modified CPM
Aperture polarization : Vertical & Horizontal
System gain for BER 10E – 3 based on capacity 99 ~ 108 dB
Traffic capacity: 2E1 ~ 16E1 G.703
Software controlled output power range: MTPC & ATPC (30 dB , 1dB step )
Transmitter Parameters:
TX output power : 30 dBm
Frequency stability : ± 5 p.p.m
Transmitter spectrum : class 1 ETSI EN 301 128 V1.2.
Maximum cable length: 200 m (50 ohm)
Receiver Parameters:
Frequency stability: ±5 ppm
Sensitivity (BER=10E-6) typical Sensitivity : -79dBm , guaranty : -77dBm
Channel spacing : 28 MHz
1+1 Hot Standby Features:
Asymmetric Switch: 2dB/3dB Insertion Loss
TX Switch Time Delay
RX Switch Time Delay
IDU11_16E1
Indoor Unit Specifications:
Electrical Specifications
E1 Line Interface Specs:
- Traffic Capacity : From 2 Up to 16 E1
- Physical Interface : G.703
- Detection and Generation of : AIS and Loss condition
- Internal Termination : 75Ω or 120Ω With electronic switch controlled by NMS software
- Dual or Quad 802.11 Ethernet Port
- Configurable Time slots for data and voice
Ethernet Interface:
- Ethernet Bridge Transceiver Minimum 2 Mb/s to Maximum 32 Mb/s (802.11protocol Supported)
- From Dual Port Up to Quad Port 10/100 Base-T Ethernet Physical Layer Transceiver
- Auto MDIX for Detection of Ethernet Cable Configuration ( straight and Crossover)
- Software Configurable Flexible bandwidth From maximum 40 Mbps down to Minimum 2Mpbs.
- Built in SNMP Ver3 Management System
Auxiliary Input port:
- Isolated and Voltage Protected Relay Control port For Applying some command from base systems
- Isolated Input Port For Get Some Environmental Alarms
- 2*10/100 Base-T port form NMS Connection and Switching the NMS Traffic Over Layer2 Switch For Cascading The Units in One Place
- Null modem Port in use NMS System Over Telephone line
Interconnection cable:
- Dual Coaxial Cable (Main & Stby)
- maximum Cable Length:100 m (50 ohm)
Power Supply :
- Single -48v Dc input Power supply With -36V Dc to -72V DC Range
- 17Watt power Consumption
1+1 Hot Standby Features:
- TX Switch Time Delay
- RX Switch Time Delay
Mechanical Specifications
- Dimensions 428mm * 44mm * 265mm
- Weight 4.5Kg