Main Standard: ETSI
Low Power Consumption
High Security
Easy Installation

4.4GHZ_16E1_11

15GHZ_16E1_11

18GHZ_16E1_11

23GHZ_16E1_10

 

ODU (Outdoor Unit):

Dimensions: (H×W×D:148*242*274.5

Weight :17kg

Temperature range: -33 ~ + 55 C

Power consumption: < 75 Watt

Box Test point: AGC

Configuration 1+1

System Parameters:

Frequency range: 4.4 to 5GHz (ITU-R F.636-3)

Frequency step : 1 MHz

Modulation type : modified CPM

Aperture polarization : Vertical & Horizontal

System gain for BER 10E – 3 based on capacity 99 ~ 108 dB

Traffic capacity: 2E1 ~ 16E1 G.703

Software controlled output power range: MTPC & ATPC (30 dB , 1dB step )

Transmitter Parameters:

TX output power : 30 dBm

Frequency stability : ± 5 p.p.m

Transmitter spectrum : class 1 ETSI EN 301 128 V1.2.

Maximum cable length: 200 m (50 ohm)

Receiver Parameters:

Frequency stability: ±5 ppm

Sensitivity (BER=10E-6) typical Sensitivity : -79dBm , guaranty : -77dBm

Channel spacing : 28 MHz

1+1 Hot Standby Features:

Asymmetric Switch: 2dB/3dB Insertion Loss

TX Switch Time Delay

RX Switch Time Delay

 

IDU11_16E1

Indoor Unit Specifications:

Electrical Specifications

E1 Line Interface Specs:

  • Traffic Capacity : From 2 Up to 16 E1
  • Physical Interface : G.703
  • Detection and Generation of : AIS and Loss condition
  • Internal Termination : 75Ω or 120Ω With electronic switch controlled by NMS software
  • Dual or Quad 802.11 Ethernet Port
  • Configurable Time slots for data and voice

Ethernet Interface:

  • Ethernet Bridge Transceiver Minimum 2 Mb/s to Maximum 32 Mb/s (802.11protocol Supported)
  • From Dual Port Up to Quad Port 10/100 Base-T Ethernet Physical Layer Transceiver
  • Auto MDIX for Detection of Ethernet Cable Configuration ( straight and Crossover)
  • Software Configurable Flexible bandwidth From maximum 40 Mbps down to Minimum 2Mpbs.
  • Built in SNMP Ver3 Management System

Auxiliary Input port:

  • Isolated and Voltage Protected Relay Control port For Applying some command from base systems
  • Isolated Input Port For Get Some Environmental Alarms
  • 2*10/100 Base-T port form NMS Connection and Switching the NMS Traffic Over Layer2 Switch For Cascading The Units in One Place
  • Null modem Port in use NMS System Over Telephone line

Interconnection cable:

  • Dual Coaxial Cable (Main & Stby)
  • maximum Cable Length:100 m (50 ohm)

Power Supply :

  • Single -48v Dc input Power supply With -36V Dc to -72V DC Range
  • 17Watt power Consumption

1+1 Hot Standby Features:

  • TX Switch Time Delay
  • RX Switch Time Delay

Mechanical Specifications

  • Dimensions 428mm * 44mm * 265mm
  • Weight 4.5Kg